Pneufit, Warning – Norgren PUSH-IN Fittings User Manual

Page 26

Advertising
background image

N/en 9.1.020.26

Pneufit

®

C

Our policy is one of continued research and development. We therefore reserve the right to amend,

without notice, the specifications given in this document. © 2014 Norgren Ltd

2006-9005e

3/14

3/2 Shut-off valves

C01GG

3/2 Shut-off valves

C01GJ

3/2 Shut-off valves

C01GH

3/2 Shut-off valves

C01GF

B

C

C1

E

G

N

O

Model

R1/8

71

40,5

19

8

18,5

18

14

C01GG1818

R1/4

77

40,5

19

10

18,5

18

14

C01GG2828

R3/8

81

41

24

11

21,5

21

17

C01GG3838

R1/2

90

41

24

14

21,5

21

21

C01GG4848

ØA

B

C

C1 *

C2

E

G

N

O *

Model

6

R1/8

62

40,5

26

19

8

18,5

18

14

C01GH0618

6

R1/4

65

40,5

26

19

10

18,5

18

14

C01GH0628

6

R3/8

66

40,5

26

19

11

18,5

21

17

C01GH0638

8

R1/8

63

40,5

27,5

19

8

18,5

18

14

C01GH0818

8

R1/4

66

40,5

27,5

19

10

18,5

18

14

C01GH0828

8

R3/8

67

40,5

27,5

19

11

18,5

21

17

C01GH0838

10

R1/4

67

41

31

24

10

21,5

18

17

C01GH1028

10

R3/8

71,5

41

31

24

11

21,5

21

17

C01GH1038

10

R1/2

74,5

41

31

24

14

21,5

21

21

C01GH1048

12

R1/4

75,5

41

34

24

10

21,5

18

19

C01GH1228

12

R3/8

76,5

41

34

24

11

21,5

21

19

C01GH1238

12

R1/2

79,5

41

34

24

14

21,5

21

21

C01GH1248

* see drawing C01GG series

ØA

B

C

C1 *

C2

E

G

N

O *

Model

6

R1/8

62

40,5

26

19

8

18,5

18

14

C01GJ0618

6

R1/4

65

40,5

26

19

10

18,5

18

14

C01GJ0628

6

R3/8

66

40,5

26

19

11

18,5

21

17

C01GJ0638

8

R1/8

65

40,5

27,5

19

8

18,5

18

14

C01GJ0818

8

R1/4

66

40,5

27,5

19

10

18,5

18

14

C01GJ0828

8

R3/8

67

40,5

27,5

19

11

18,5

21

17

C01GJ0838

10

R1/4

70,5

41

31

24

10

21,5

18

17

C01GJ1028

10

R3/8

71,5

41

31

24

11

21,5

21

17

C01GJ1038

10

R1/2

74,5

41

31

24

14

21,5

21

21

C01GJ1048

12

R1/4

75,5

41

34

24

10

21,5

18

19

C01GJ1228

12

R3/8

76,5

41

34

24

11

21,5

21

19

C01GJ1238

12

R1/2

79,5

41

34

24

14

21,5

21

21

C01GJ1248

* see drawing C01GG series

ØA

C

C1 *

E

N

O *

Model

6

52,5

40,5

19

18,5

18

C00GF0600

8

53

40,5

19

18,5

18

C00GF0800

10

62

41

24

21,5

21

C00GF1000

12

68,5

41

24

21,5

21

C00GF1200

* see drawing C01GG series

1

Exhaust bore hole

Warning

These products are intended for use in industrial compressed air
systems only. Do not use these products where pressures and
temperatures can exceed those listed under »Technical features«.

Before using these products with fluids other than those specified,
for non-industrial applications, life-support systems, or other ap-
plications not within published specifications, consult NORGREN.

Through misuse, age, or malfunction, components used in
fluid power systems can fail in various modes.

The system designer is warned to consider the failure modes
of all component parts used in fluid power systems and to provide
adequate safeguards to prevent personal injury or damage to
equipment in the event of such failure.
System designers must provide a warning to end users in
the system instructional manual if protection against
a failure mode cannot be adequately provided.
System designers and end users are cautioned to review specific
warnings found in instruction sheets packed and shipped with
these products.

C

E

ø 4,3

N

B

C 1

G

O

1

2

1

C

E

ø 4,3

N

B

G

C2

ø

A

C

E

ø 4,3

2

1

N

B

G

C2

ø

A

C

E

1

2

ø

A

ø 4,3

N

Advertising