c. Secure the battery carrier to the ServeRAID adapter with the screws that

came with the battery pack.

10. Turn the ServeRAID-MR10is adapter so that the ServeRAID-MR10is adapter

keys align correctly with the connector on the system board.

Attention:

Incomplete insertion might cause damage to the system board or

the ServeRAID-MR10is adapter.

1

ServeRAID-MR10is connector

2

PCI slot 1

11. Press the ServeRAID-MR10is adapter firmly into the connector on the system

board.

12. Rotate the power-supply cage assembly out of the chassis. Lift up the

power-supply cage handle and pull the power-supply cage assembly all the
way up until the retainer latch locks the cage in place on the chassis.

120

ThinkServer TD200 Types 3724, 3808, 3809, 3815, 3817, 3824, 3826, 3836: Installation and User Guide