Operator information panel

The following illustration shows the LEDs on the operator information panel on the
front of the server.

1

System power-on LED

2

Hard disk drive activity LED

3

System-locator LED

4

System-information LED

5

System-error LED

v

Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.

v

See the Hardware Maintenance Manual to determine which components are customer replaceable units
(CRUs) and which components are field replaceable units (FRUs).

v

If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.

Lit EasyLED; diagnostic LEDs with the
system-error or information LED also lit

Description

System power-on (green)

The states of the power-on LED are as follows:

v

Off: ac power is not present, or the power supply or the LED itself
has failed.

v

Flashing rapidly (4 times per second): The server is turned off
and is not ready to be turned on. The power-control button is
disabled. Approximately 3 minutes after the server is connected to
ac power, the power-control button becomes active.

v

Flashing slowly (once per second): The server is turned off and is
ready to be turned on. You can press the power-control button to
turn on the server.

v

Lit: The server is turned on.

v

Fading on and off: The server is in a reduced-power state. To
wake the server, press the power-control button or use the IMM
Web interface.

Chapter 4. Server controls, LEDs, and power