• If you are using a ThinkServer RAID 700 Adapter, do the following:

1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector

3

on one end of the

cable to the ports 3-0 on the RAID card. Then, connect the mini-SAS connector

4

on the other end

of the cable to the mini-SAS ports 0-3 on the backplane.

2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS

signal cable. Connect the mini-SAS connector

1

on one end of the cable to the ports 7-4 on the

RAID card. Then, connect the mini-SAS connector

2

on the other end of the cable to the mini-SAS

ports 4-5 on the backplane.

Refer to the following topics for information about the connector locations:

“Hot-swap hard disk drive backplane” on page 29

“RAID card” on page 27

“System board components” on page 33

System board components

The following illustration shows the component locations on the system board.

Figure 22. System board components

1

Front panel connector

17

Riser card assembly 1 slot

2

Internal USB connector 1

18

Riser card assembly 2 slot

3

Internal USB connector 2

19

Redundant power supply connector 1