Page 10 - Installing Software Upgrade
Software Upgrading and Installation
Upgrade Steps
Explanation
Step 3 
Uninstall the existing IPNC 2.2 Manager software 
from the PC. 
 
Install the new IP Office Admin Suite 3.2 from the 
CD, see page 13. 
 
 
Failure to un-install the 2.2 build will result in 
software clashes. 
The installation procedure is similar to 
installing a new system. 
Step 4 
Open the IPNC Manager from Program 
Files\Avaya\IP Office Admin Suite. (Administrator 
default password is Administrator.) 
From File|Change Working Directory ensure that the 
working directory is set as: 
C:\Program Files\Avaya\IP Office\Manager. 
 
 
Note: 
This may have been set to: 
C:\Program Files\Alchemy\Manager by default.
Step 5 
In the directory C:\Program Files\Avaya\IP 
Office\Manager rename the file nadrcii.bin file to 
nadrciiold.bin. 
 
This is the 3.2(19) software. 
 
Use Explorer to copy the nadrcii.bin file from the 
D:\bin\2.2(1076) directory on the new CD to the 
directory C:\Program Files\Avaya\IP 
Office\Manager. 
 
This is the 2.2(1076) software. 
 
 
The original nadrcii.bin (now called 
nadrciiold.bin) file will need to be renamed to 
nadrcii.bin to upgrade to 3.2 firmware 
described later in Step 13 
 
Step 6 
From the IPNC Manger, open UpgradeWiz 
(File|Advanced|Upgrade). Right click in the 
UpgradeWiz window and Select Directory as 
D:\bin\2.2 (1076). Select the nadrcii.bin file, click 
OK. In UpgradeWiz, 2.2 (1076) will appear as 
Available. Click Upgrade to load the 2.2 (1076) 
firmware image to the IPNC. 
 
Note: It is preferable to use a static IP address from 
the PC configured to the IPNC subnet.
 
The IPNC 2.2 (1076) build is only required to 
upgrade the IPNC Boot Loader from version 
1.3 to 1.7. 
Boot Loader 1.7 is required to support IPNC 
3.x firmware. 
 
IPNC 2.2 (1076) firmware must not be used 
operationally. It is for upgrade purposes 
only. 
Step 7 
When the IPNC reboots and is operational with 
IPNC 2.2(1076) firmware, type the following 
command on the DTE maintenance port (see Step 
1). 
at-debug 
This will return the following prompt 
<DRC Manager Version 0.1> 
Tue 27/8/2002 11:18:51, Hello> 
 
When the IPNC is operational the Green 
status LED should be ‘on’ and Red status LED 
should be ‘off’. 
The upgrade, via UpgradeWiz, shows the 
rebooting sequence. If the upgrade process 
finishes and says it has failed, ignore and 
press OK. 
Page 10 - Software Upgrading and Installation
INDeX IPNC Cassette Administration Manual
Installing Software Upgrade
38DHB0002UKDD – Issue 7 (22/11/02)