Avaya 38DHB0002UKDD User Manual
Page 11
 
Software Upgrading and Installation
Installing Software Upgrade - Page 11
Upgrade Steps
Explanation
Step 8 
At the debug prompt type the following command: 
ipoffice 
 
Step 9 
If the previous steps have been followed correctly 
and the upgrade is successful thus far to loader 
version 1076, an output similar to the following will 
be shown. 
Tue 27/8/2002 11:30:28, Hello>ipoffice
This is irreversible. Continue (Y/N)? 
Press Y on the keyboard. 
 
 
If the previous steps have been followed 
correctly and the upgrade to 1076 is 
successful the following output will be shown. 
New Boot Sector process 
Checking new loader code 
New loader code checksum = 
0x2EABEEAC, (wanted 0x2EABEEAC) 
Saving current feature table 
Mac address is 00E007005C27 
********************************** 
ERASING and PROGRAMMING LOADER
********************************** 
********************************** 
DONE
********************************** 
Tue 27/8/2002 11:31:28, Hello> 
Step 10 
Reboot the IPNC by typing the following command 
at the debug prompt. 
reboot 
e.g. 
Tue 27/8/2002 11:31:28, Hello>
reboot 
 
Step 11 
When the IPNC has finished the boot sequence and 
the green LED comes on and the Red LED is off, 
unplug the IPNC from the INDeX. 
 
Step 12 
In order to confirm the IPNC is running the 1.7 
Loader image, plug in the IPNC and press ‘Esc’ on 
the keyboard within 3 seconds. 
The following output will be shown indicating the 
upgrade procedure is successful. 
P5 Loader 1.7 (2MB-2xF800 Flash-120nS 
SDRAM-10) 
CPU Revision 0x0502 
To quit this mode and continue at the prompt 
sequence type: atf 
 
 
Pressing the ‘Esc’ in this way causes the 
IPNC to stop the image load to allow direct 
access to the loader mode. 
 
INDeX IPNC Cassette Administration Manual
Software Upgrading and Installation - Page 11
38DHB0002UKDD – Issue 7 (22/11/02)
Installing Software Upgrade