Page 12 - Installing Software Upgrade
Software Upgrading and Installation
Upgrade Steps
Explanation
Step 13 
Once the IPNC has been restarted load the IPNC 
3.x firmware using the Manger UpgradeWize 
(File|Advanced|Upgrade). 
In step 2, the nadrcii.bin was renamed nadrcii.old. 
For the 3.2 version of IPNC firmware this must be 
renamed back from nadrcii.old to nadrcii.bin. The 
2.2(1076) bin file can be renamed appropriately. 
 
 
Note: 
Loader v1.7 is compatible with IPNC 2.2 or 3.2 
software for operational use. If IPNC 3.2 is to 
be loaded then the loader must be v1.7. 
When the upgrade via the wizard shows the 
rebooting sequence. 
If the upgrade process finishes and says it has 
failed, ignore and press OK. 
 
Step 14 
Check the firmware variant by opening the upgrade 
wizard again and see the Unit build number (3.2/19) 
 
To prove that upgrade is successful use the 
Refresh button on the Upgrade Wizard to 
update the display. 
Confirm that the version shown in the Version 
column is the same as that shown in the 
Available column. 
 
Step 15 
Restart the IPNC with 3.2 software and ensure that 
it is defaulted to factory settings as follows: 
Using IPNC Manager: 
Open File|Advanced|eraseConfig (factory Default). 
Or 
Using HyperTerminal: 
Unplug the IPNC. Plug in the IPNC and press the 
'Ecs' key every second until the Loader message 
appears. 
Enter AT return 
Enter AT-X2 return 
Enter AT-X3 return 
Unplug the IPNC and plug in again. 
 
 
When connecting for the first time via the 
Manager after defaulting, please check that 
the DHCP Server address range is 200 to 
LAN 1 and LAN 2. 
If these are blank then DHCP will fail. 
Page 12 - Software Upgrading and Installation
INDeX IPNC Cassette Administration Manual
Installing Software Upgrade
38DHB0002UKDD – Issue 7 (22/11/02)