Konica Minolta Magicolor 6100 Series User Manual
Page 23
Configuring a Port
21
The following timeouts are used by the Crown Print Monitor when transporting print
jobs to the print device and reporting their print status to Print Manager:
a
Status update interval
Determines how often the Crown Print Monitor updates Print Manager with sta-
tus information on the print device attached to the port. Scroll through the list box
and select a value between 1 and 600 seconds. The default is 5 seconds.
b
Status request timeout
Sets the amount of time that the Crown Print Monitor waits for a response from
the print device before notifying Print Manager that the device is not responding.
Scroll through the list box and select a value between 1 and 600 seconds. The
default is 10 seconds.
c
Send request timeout
Sets the amount of time that the Crown Print Monitor waits for a print job to be
sent before it returns control to the Microsoft Windows 2000/Me/98/95 Print
Spooler. Scroll through the list box and select a value between 1 and 600 minutes.
The default is 60 minutes.
8
Configure the audible alert.
This setting enables the Crown Print Monitor’s problem alert sound. Click the Audi-
ble Alert check box to have the monitor beep the system speaker when it encounters
an error writing to the port. A clear check box disables the problem alert sound.
9
Choose OK.
If this timeout expires and the job
was sent via...
Then this is what happens...
Windows Me/98/95 Server
The print job is automatically terminated and
cleared from the system.
Workstation
Windows Me/98/95 Print Spooler dialog box dis-
plays asking for a retry or cancel response.
Regardless of your response, the
job is terminated and cleared from
the system.