1 initialize method, Initialize method – Konica Minolta BIZHUB C360 User Manual

Page 25

Advertising
background image

Security Function Ver. 1.02 Jul. 2010

8. Service Mode functions

21

bizhub C360/C280/C220

for PKI Card System

Security Function

8.5.1

Initialize method

1.

Call the Service Mode to the screen.

See P.3

2.

Touch [System 1].

3.

Touch [Initialization].

4.

Select [Clear All Data] or the clear item in [Clear Individual Data] and press the Start
key.

5.

When “OK” is displayed, turn off the main power switch and turn it on again more than
10 seconds after.

NOTE
When the Clear All Data function has been executed, be sure to make the following
settings again.
• Since the CE Password is reset to the default value, be sure to set once again a CE

Password that meets the requirements of the Password Rules.

• Since the Administrator Password is reset to the default value, be sure to have the

administrator of the machine set once again an Administrator Password that
meets the requirements of the Password Rules.

• Since the SNMP Password v3 is reset to the default value (MAC address), be sure

to have the administrator of the machine set once again a password that meets the
requirements of the Password Rules.

• If you leave the site with the Service Mode setting screen being displayed, unau-

thorized changes could occur for any set values. When you finish the setting of
Service Mode, or if you have to leave the site by necessity when the Service Mode
has been set, be sure to press [Exit] to the main screen.

When the Clear Individual Data (Network Setting Data) function has been executed,
be sure to make the following settings again.
• Since the SNMP Password v3 is reset to the default value (MAC address), be sure

to have the administrator of the machine set once again a password that meets the
requirements of the Password Rules.

A0EDS1E037DA

Advertising