Security Function Ver. 1.02 Jul. 2010

10. Firmware rewriting

31

bizhub C360/C280/C220

for PKI Card System

Security Function

13. Call the Service Mode to the screen.
14. Select [Firmware Version].
15. Make sure if the version of firmware is updated.

10.2.3

Action when data transfer fails

• If “NG” appears on the control panel, indicating that rewriting has been unsuccessful (in

which case the Start key lights up red), take the following steps.

1.

Perform the data rewriting procedure again.

2.

If the procedure is abnormally terminated, change the USB memory for a new one and
try another rewriting sequence.

3.

If the procedure is still abnormally terminated, change the board that has caused “NG”
and carry out data rewriting procedure.

A0EDS1E042DA

F/W to be updated

Appropriate board

Remark

MFP CONTROLLER

MFP board (MFPB)

SCANNER

MFP board (MFPB)

PRINTER

Printer control board (PRCB)

FAX BOARD CONTROLLER1 Fax board (Main)

Only when the FK-502 is mounted

FAX BOARD CONTROLLER2 Fax board (Sub)

Only when the FK-502 is mounted

ADF (DF-M)

DF control board (DFCB)

FINISHER

FNS control board (FSCB)

Only when the FS-527/529 is
mounted

RU

Transfer control board (TRCB)

SD

SD drive board (SDDB)

Only when the SD-509 is mounted

DSC1

DSC board

Only when the SC-507 is mounted

DSC2

Not used