9

Installing the Unit

Step 1:

Position Unit Near Installation Area

Move unit so that it is within four feet of the desired area
of installation.

Step 2:

Connect Water Inlet Hoses

NOTE: Refer to Section on Water Supply
Requirements
before connecting water inlet hoses.

Remove the four plain rubber washers from accessories
bag, and install them according to the illustration.

Turn on the water supply faucets and flush the lines for
approximately two minutes to remove any foreign
materials that could clog the screens in the water mixing
valve.

NOTE: When installing in newly constructed or
renovated building, it is very important to flush the
lines since build-up may have occurred during
construction.

IMPORTANT: Thread hose couplings onto valve
connections finger-tight, then approximately 1/4 turn
with pliers. DO NOT cross thread or overtighten
couplings.

Turn water on and check for leaks. If leaks are found,
retighten the hose couplings. Continue tightening and
rechecking until no leaks are found.

. . .

Washer and dryer are not designed to be
operated as separated, side-by-side units.

W187

CAUTION

H243I

RUBBER WASHER

(Plain)

H091IE1A

INSTALL THIS

END OF HOSE

TO WATER

SUPPLY FAUCET

INSTALL THIS END OF HOSE

TO VALVE CONNECTIONS

AT REAR OF WASHER

INLET
HOSE

RUBBER WASHER

(Plain)

H096IE1A

WATER
SUPPLY

FAUCETS

WATER

INLET

HOSES

COLD WATER
CONNECTION

WATER

MIXING VALVE

HOT WATER

CONNECTION

Advertising