11

Step 4: (Gas Dryer ONLY)

Connect Gas Supply Pipe

For further assistance, refer to Section on Gas
Requirements
.

1. Make certain dryer is equipped for use with the type

of gas in laundry room. Dryer is equipped at the
factory for Natural Gas with a 3/8" NPT gas
connection.

2. Remove the shipping cap from the gas connection at

the rear of the dryer. Make sure you do not damage
the pipe threads when removing the cap.

3. Connect to gas supply pipe using a new flexible

stainless steel connector.

4. Tighten all connections securely. Turn on gas and

check all pipe connections (internal & external) for
gas leaks with a non-corrosive leak detection fluid.

5. For L.P. (Propane) gas connection, refer to Section on

Gas Requirements.

3/8" NPT

GAS CONNECTION

1/8" NPT

PIPE PLUG

(For checking

inlet gas pressure)

NEW

STAINLESS STEEL

FLEXIBLE

CONNECTOR

USE ONLY

IF ALLOWED

BY LOCAL

CODES

(Use

Design A.G.A.

Certified

Connector)

EQUIPMENT

SHUT-OFF

VALVE

Install within

6' (1.8 m) of dryer

D434IE3A

BLACK IRON PIPE
Shorter than 20' (6.1 m) - use 3/8" pipe
Longer than 20' (6.1 m) - use 1/2" pipe