Location Requirements

Select a location with a solid floor.

The unit must not be installed or stored in an area where
it will be exposed to water and/or weather.

Leveling legs can be adjusted from inside the unit with a
9/16" deep well socket. All four legs must rest firmly on
the floor so the weight of the unit is evenly distributed.
The unit must not rock and must be level from side-to-
side and front-to-back.

IMPORTANT: Unless completely assembled, DO
NOT slide the unit across the floor. DO NOT slide the
unit more than four feet once the leveling legs have
been extended, as the legs and the base could become
damaged.

The unit needs sufficient clearance and an adequate air
supply for proper operation and ventilation, and for easier
installation and servicing. (Minimum clearances are
shown below.)

. . .

NOTE: Shaded areas indicate adjacent structure.

A

B

E

C

E

D

H245IE1A

Dryer And Exhaust Duct Clearances

Area

Description

Minimum Clearance

A

Left Dryer Side

0" (0 cm)

B

Right Dryer Side

1" (2.54 cm)

C

Dryer Top

6" (15.24 cm)

D

Dryer Rear

2" (5.1 cm)

E

Exhaust Duct Clearance to Combustible Materials

2" (5.1 cm)