Parameter

Setting range and initial value

Display

Lo1-Lo9
(Initial values: 430F: Lo8, 438F: Lo7)

The starting-up speed at the sewing start can
be adjusted.

* The smaller the number, the slower the start.
* This is used to stop the thread from pulling

out at the sewing start, and at times when
skipped stitches might easily occur.

430F: Medium-weight materials (-03), knitted wear (-0K), foundation garments (-0F)

Lo1 Lo2 Lo3 Lo4 Lo5 Lo6 Lo7 Lo8 Lo9

Sewing speed

for 1st stitch

200 200 300 400 400 400 400 800 1500

Sewing speed

for 2nd stitch

200 300 400 400 500 600 800 1200

3000

Sewing speed

for 3rd stitch

300 400 500 600 800 800 1200

2500

3200

Sewing speed

for 4th stitch

500 600 700 900 1200

1200

2500

3200

3200


430F: Heavy-weight materials (-05)

Lo1 Lo2 Lo3 Lo4 Lo5 Lo6 Lo7 Lo8 Lo9

Sewing speed

for 1st stitch

200 200 300 400 400 400 800 1500

1500

Sewing speed

for 2nd stitch

200 300 400 400 600 800 1200

2000

3000

Sewing speed

for 3rd stitch

300 400 500 600 800 1200

2500

2500

3200

Sewing speed

for 4th stitch

500 600 700 900 1200

2500

3200

3200

3200


438F

Lo1 Lo2 Lo3 Lo4 Lo5 Lo6 Lo7 Lo8 Lo9

Sewing speed

for 1st stitch

200 200 300 300 300 400 400 400 400

Sewing speed

for 2nd stitch

200 200 300 300 400 400 400 600 900

Sewing speed

for 3rd stitch

300 300 300 400 400 400 600 900 1500

Sewing speed

for 4th stitch

300 400 400 400 400 400 900 2000

2000

Slow start

pattern

* The speed will not be faster than the sewing speed which has been set.
* The thread nipper device will not operate for settings other than Lo8 and Lo9.

Upper thread

tension

0 - 300
(Initial setting is “75”.)

* The later the value, the stronger the upper

thread tension.

2409B

Initial value

Initial value

2456B

(sti/min)

(sti/min)

(sti/min)

Advertising