7. replacing the movable knife and fixed knife – Brother BE-438F User Manual

Page 77

Advertising
background image

9. STANDARD ADJUSTMENT

68

KE-430F, BE-438F

9-7. Replacing the movable knife and fixed knife





















1. Open the shuttle race cover, remove the two screws (1), and then remove the feed plate (2).
2. Remove the two screws (3) and the two flat screws (4), and then remove the needle plate (5).
3. Remove the movable knife (6) and the fixed knife (7).
























4. Install new fixed knife (7) in the position shown in the illustration.
5.

Apply grease to the outside of the collar (8) and the shoulder screw (9), and then install the new movable knife (6) together
with the thrust washer (10) and movable knife spacer (11).

6.

Check that the movable knife (6) and the fixed knife (7) cut the thread cleanly.

7. Apply grease to the pin (12) of the movable knife, and then insert it into the hole in the movable knife connecting plate (13).

Then, while placing the pin (15) of thread nipper connecting plate F into the hole in thread nipper D (14), install the needle
plate (5).

8. Check that the center of the needle hole and the needle are aligned.

Select an accessory movable knife spacer (11) which allows
the movable knife (6) to cross over the fixed knife (7) with a
force that is as gentle as possible while still allowing the
thread to be trimmed.
* Move the movable knife (6) as shown in the illustration

and check that it trims the thread cleanly.

Note:

If the movable knife spacer (11) is too thick, it will not be
possible to trim the thread.

2331B

2333B

2332B

2334B

Advertising
This manual is related to the following products: