4. using the production counter – Brother BE-438F User Manual

Page 57

Advertising
background image

6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)

48

KE-430F, BE-438F

6-4. Using the production counter

<Setting the counter value>

1

Change the mode to production counter setting
mode.

SPEED indicator illuminates

TEST indicator and COUNTER indicator illuminate

While pressing the TEST key, press the

key.


࡮ The 7 digits of the current counter value will be

displayed in the PROGRAM No. display and the
menu display.

2

Change the counter value.

Press the

or key (1) to set the counter value.

• The counter value can be set from [000][0000] to

[999][9999].

• If you press the RESET key during setting mode, the

value will become [000][0000].

• If the value is changed, the display will change to

flashing.

3

Apply the changed parameter setting.

Press the ENTER key.

࡮ The value will be applied and the display will change

to illuminated.

࡮ If you press the TEST key without pressing the

ENTER key, you can cancel the parameter changes.

4

Ending setting mode

TEST indicator switches off

Press the TEST key.

<Production counter operation>

The production counter is always operating. (It operates even if the production counter display is not active.) If you press the SELECT
key so that the COUNTER indicator illuminates when memory switch No. 300 is ‘ON’, the current production counter value will be
displayed in the menu display instead of the lower thread counter value. (The SPEED indicator will also illuminate at this time.)

1. The counter is incremented by 1 each time one sewing

operation is complete. If the production counter display is
active, the number being displayed in the menu display (1)
will be incremented by 1.

* If you would like the digits to be displayed in all columns,

use the temporary display function described below.

* If you press the RESET key (2) for 2 seconds or more, the

counter value can be reset to [0000].

Temporary display function
࡮ While pressing the ENTER key, press the F1 key. The

production counter will be displayed as 7 digits while the
keys are being pressed.

࡮ While pressing the ENTER key, press the F2 key. The

lower thread counter will be displayed while the keys are
being pressed.

2429B 2430B

2414B

2404B

2432B

For example,

1,234,500.

2431B