Four Wire Range Cord Connection

(Recommended Method)

1. Disconnect electrical power at breaker box.
2. Remove the terminal block cover to expose the terminal block

3. Remove top nut, star washer, and round washer from each post.

Note: DO NOT remove last round washer, last nut or internal wiring leads.

4. Remove screw from bottom end of ground strap.
5. Remove ground strap from center post, rotate so that wide end is at top and

attach wide end to range through hole below junction box. Attach green wire
on top of ground strap. Tighten Screw.

6. Attach red wire, round washer, star washer and nut IN THIS ORDER to left

post.

7. Attach white wire, round washer, star washer and nut IN THIS ORDER to cen-

ter post.

Figure 10: 4 Wire Connection

Figure 11: Four Wire Range cord Connection - Ground Strap and Wire

ground strap

green ground screw

ground wire