Bosch BOSCH OVEN User Manual

Page 15

Advertising
background image

English 13

8. Strip 3/8 (9.53 mm) inches of insulation from the end of the wire.

9. Insert the insulated grounding wire into the lug below the terminal block.
10. Insert stripped end of white wire into the center lug. Secure the clamping-

screw.

11. Insert stripped end of red wire into the left lug. Secure clamping screw.
12. Insert black wire into the right lug. Secure clamping screw. Tighten each

clamping screw with the appropriate torque (see table).

13. Properly secure flexible conduit at knockout on angle and at supply side junc-

tion box. The wiring is now complete.

Figure 16:

Wire Stripping

Figure 17:

Attaching Wire to Lug

Table 3: Appropriate Torque Levels for Aluminum or Copper Wire

Gauge

Torque (in./lbs.)

Torque (Nm)

6

35

3.95

8

25

2.82

Figure 18:

Completed Four Wire Flexible Conduit Connection

3/8 “

lug

clamping screw

wire

red wire

white wire

green

ground

screw

black wire

green ground wire

Advertising