Cleaning the drum unit, Cleaning the drum unit -23 – Brother DCP-8025D User Manual

Page 251

Advertising
background image

14 - 23 TROUBLESHOOTING AND ROUTINE MAINTENANCE

3

Gently clean the scanner window by wiping it with a clean soft
dry cloth. Do not use isoproply alcohol.

Cleaning the drum unit

We recommend placing the drum unit and toner cartridge assembly
on a cloth or large disposable paper to avoid spilling and scattering
toner.

1

Clean the primary corona wire inside the drum unit by gently
sliding the blue tab from right to left several times.

2

Return the blue tab and snap it into the Home position (

).

Caution

If the blue tab is not at the Home position (

), printed pages may

have vertical stripes.

3

Reinstall the drum unit and toner cartridge assembly into the
DCP. (See Replacing the drum unit on page 14-29.)

4

Close the front cover.

5

Plug in the power cord.

Laser Scanner Window

Corona Wire

Tab

Home Position(

▼)

Advertising