Figure 18 examples of airflow symbols, Replacing a power supply unit, Figure 18 – Brocade Communications Systems Brocade ICX 6650 53-1002599-01 User Manual

Page 57: Example

Advertising
background image

Brocade ICX 6650 Hardware Installation Guide

41

53-1002599-01

Replacing a power supply unit

5

You can use external labels as a guide. The power supplies and fan assemblies are labeled with an
airflow symbol on the faceplate to indicate whether the assembly takes in or exhausts air. The
symbol also appears on the top of the FRU. All FRUs in a chassis must have the same label affixed
so that airflow direction is consistent.

Figure 18

illustrates examples of the airflow labels.

FIGURE 18

Examples of airflow symbols

The green E symbol indicates an exhaust FRU. This unit pulls air in from the front of the switch and
exhausts it out the rear side. This is called front-to-back airflow or forward airflow.

The orange I symbol indicates an intake FRU. This unit pulls air in from the rear side of the switch
and exhausts it out the front side. This is called back-to-front airflow or reverse airflow.

The show chas command displays a device’s airflow direction: Front-to-Back or Back-to-Front.

Replacing a power supply unit

CAUTION

Remove the power cord from a power supply before you install it in or remove it from the device.
Otherwise, the power supply or the device could be damaged as a result. (The device can be
running while a power supply is being installed or removed, but the power supply itself should not
be connected to a power source.)

CAUTION

For the Brocade ICX 6650 devices, be sure that the airflow direction of the power supply unit
matches that of the installed fan tray. The power supplies and fan trays are clearly labeled with
either a green arrow with an “E”, or an orange arrow with an “I.”

ATTENTION

Maintain all power supply and fan assemblies in operational condition to provide redundancy.

CAUTION

Because the cooling system relies on pressurized air, do not leave any of the power supply and
fan assembly slots empty longer than two minutes while the switch is operating. If a power supply
or fan assembly fails, leave it in the switch until it can be replaced.

AIRFLOW

E

AIRFLOW

Advertising