Environmental considerations

A

Environmental considerations

Table 4

lists the acceptable environmental ranges for both operating and nonoperating (such as

during transportation or storage) conditions.

Cooling system and fans

Fans cool the CPU, main memory, and voltage regulators. For Brocade ICX 6650 switches, the fans
use either:

An exhaust airflow which moves air from front to back. See

Figure 19

. Devices with exhaust

airflow are labeled with a green arrow with “E.” See

Figure 20

.

An intake airflow which moves air from back to front. See

Figure 21

. Devices with intake airflow

are labeled with an orange arrow with “I.” See

Figure 22

.

CAUTION

Be sure that the airflow direction of the power supply unit matches that of the installed fan tray.
The power supplies and fan trays are clearly labeled with either a green arrow with an “E” for
exhaust, or an orange arrow with an “I” for intake.

TABLE 4

Environmental requirements

Condition

Acceptable during operation

Acceptable during non-operation

Ambient
Temperature

0º to 40ºC (32º to 104ºF)

-25º to 70ºC (-23º to 158ºF)

Humidity

10% to 95% RH non-condensing, at
40ºC (104ºF)

5% to 80% RH non-condensing, at 70ºC
(158ºF)

Altitude

0 to 3 km (9,842 feet) above sea level

0 to 12 km (39,370 feet) above sea level

Shock

20 G, 6 ms, half-sine wave

33 G, 11 ms, half-sine wave, 3/eg Axis

Vibration

0.5 G sine, 0.4 gms random, 5-500 Hz

2.0 G sine, 1.1 gms random, 5-500 Hz

Airflow

Maximum - 90.1 cmh (53 cfm)
Nominal - 59.5 cmh (35 cfm)

N/A

Heat
dissipation

478 BTU/hr

N/A

Operating
noise

46.7 dB

N/A