11. SNMP services

3. In the “Security” tab, the default Community is called ‘public’ and is read-only.

You may want to give read-write permission to ‘public’ (not recommended) or create a ‘private’ community
with read-write permissions.

4. In the Control Server, enable the SNMP support, and optionally, enable read-write support.

5. The SNMP service should be restarted, to take the changed settings into account.

To uninstall the snmp agent: regsvr32 /u IQProSNMP.dll

11.2 SNMP integration

Commands

Following commands are provided stored in the MIB :

Command

Type

PROJECTORTYPE

READ

SERIALNUMBER

READ

LAMPPRODUCTNUMBER

READ

LAMPSERIALNUMBER

READ

SERVERTYPE

READ

SERVERVERSION

READ

EMBEDDEDSOFTWAREVERSION

READ

PROJECTORLANGUAGE

READ

PROJECTORNAME

READ

LOCATION

READ

ORIENTATION

READ

RESOLUTION

READ

DESKTOPRESOLUTION

READ

PROJECTORSTATE-cooldown

READ

PROJECTORSTATE-textbox

READ

PROJECTORSTATE-projector

READ/WRITE

PAUSE

READ/WRITE

FREEZE

READ/WRITE

PROJECTORRUNTIME

READ

LAMPWARNINGSTATUS

READ

LAMPALERTSTATUS

READ

LAMPMODE

READ/WRITE

LAMPRUNTIME

READ

LAMPSTATUS

READ

LAMPWARNINGTIME

READ/WRITE

I2CDIAGNOSTICS

READ