Billion Electric Company BiPAC 8501/8521 User Manual

Page 115

Advertising
background image

Billion BiPAC 8500/8501/8520/8521 SHDSL (VPN) Firewall Bridge/ Router

Chapter 4: Configuration

111

more powerful but increase the latency.

DES: Stands for Data Encryption Standard, it uses 56 bits encryption

method.

3DES: Stands for Triple Data Encryption Standard, it uses 168 (56*3) bits

encryption method.

AES: Stands for Advanced Encryption Standards, you can use 128, 192 or

256 bits encryption method.

o

Diffie-Hellman Group: It is a public-key cryptography protocol that allows two

parties to establish a shared secret over an unsecured communication channel
(i.e. over the Internet). There are three modes, MODP 768-bit, MODP 1024-bit
and MODP 1536-bit. MODP stands for Modular Exponentiation Groups.

o

Local ID:

Type: Specify a local ID type.

Content: Input ID information, like domain name

www.ipsectest.com

.

o

Remote ID:

Type: Specify a Remote ID type.

Identifier:

Input

remote

ID

information,

like

domain

name

www.ipsectest.com

.

o

SA Lifetime: Specify the number of minutes that a Security Association (SA) will

stay active before a new encryption and an authentication key will be exchanged.
There are two kinds of SAs, IKE and IPSec. IKE negotiates and establishes SA on
behalf of IPSec, an IKE SA is used by IKE.

Phase 1 (IKE): To issue an initial connection request for a new VPN tunnel.

The range can be from 5 to 15,000 minutes, and the default is 240 minutes.

Phase 2 (IPSec): To negotiate and establish a secure authentication. The

range can be from 5 to 15,000 minutes, and the default is 60 minutes.

Note: A short SA time increases security by forcing two parties to update the keys. However,
every time the VPN tunnel re-negotiates, access through the tunnel will be temporarily
disconnected.

PING to Keepalive: It is used to detect IPSec tunnel connection failure. Connection

failure is defined as abort or in NO response state. In such event Ping to Keepalive takes
proper action to ensure the connection quality of IPSec.

o

PING to the IP: It can IP Ping the remote PC with the specified IP address and

issue alert when the connection fails. Once alter message is received, Router will
drop this tunnel connection. Re-establishing of this connection is required. Default
setting is 0.0.0.0 which disables the function.

o

Interval: This sets the time interval of Pings to the IP function to monitor the

connection status. Default interval setting is 10 seconds. Time interval can be set

Advertising