581c024-060 – Bryant 581C User Manual

Page 14

Advertising
background image

14

**ARI* CAPACITY RATINGS — 581C024-060

LEGEND

*Air-Conditioning & Refrigeration Institute.

**ARI does not require EER ratings for unit with capacity below 65,000 Btuh. For

these units, the EER rating at ARI standard conditions is provided for informa-
tion only.

NOTES:

1. Rated in accordance with ARI Standard 210-94 or 360-93.
2. Ratings are net values, reflecting the effects of circulating fan heat.
3. Ratings are based on:

Cooling Standard: 80 F db, 67 wb indoor entering-air temperature and 95 F
db outdoor entering-air temperature.
IPLV Standard: 80 F db, 67 F wb indoor entering-air temperature and 80 F
db outdoor entering-air temperature.

4. All 581C024-060 units are in compliance with ASHRAE 90.1 2001, 2004

Energy Standard for minimum SEER and EER requirements. Refer to state
and local codes or visit the following website: http://bcap-energy.org to
determine if compliance with this standard pertains to a given geographical
area of the United States.

HEATING CAPACITIES AND EFFICIENCIES — 581C024-060

208/230-1-60 — SINGLE-STAGE GAS HEAT

208/230-1-60 — SINGLE-STAGE GAS HEAT — LOW NOx

AFUE — Annual Fuel Utilization Efficiency

NOTE: Capacities for stainless steel heat exchanger units (S/R/T) are the same
as standard units (D/E/F).

UNIT
581C

NOMINAL

TONS

COOLING

(Btuh)

TOTAL

kW

SEER

EER

SOUND RATING

(decibels)

024

2

24,000

3.2

14.1

12.0**

76

036

3

36,200

4.1

14.0

11.8**

76

048

4

46,000

5.5

14.0

11.7**

76

060

5

59,000

6.7

14.0

11.9

80

EER

—

Energy Efficiency Ratio

SEER

—

Seasonal Energy Efficiency Ratio

UNIT

INPUT CAPACITY

OUTPUT CAPACITY

TEMPERATURE

MINIMUM HEATING

EFFICIENCY

581C

1st Stage

2nd

Stage

1st Stage

2nd Stage

RISE (°F)

AIRFLOW (CFM)

AFUE (%)

Steady State

(%)

024050

50,000

—

40,500

—

25-65

575

81.00

81

036072

72,000

—

59,040

—

25-55

1004

82.80

82

036115

115,000

—

92,000

—

55-85

1002

80.00

80

048072

72,000

—

58,000

—

25-55

1004

82.80

82

048115

115,000

—

92,000

—

35-65

1320

81.00

81

048150

150,000

—

118,000

—

50-80

1396

80.40

80

060072

72,000

—

58,000

—

25-55

1004

82.80

82

060115

115,000

—

92,000

—

35-65

1327

81.00

81

060150

150,000

—

118,000

—

50-80

1314

80.40

80

UNIT

INPUT CAPACITY

OUTPUT CAPACITY

TEMPERATURE

MINIMUM HEATING

EFFICIENCY

581C

1st Stage 2nd Stage

1st Stage 2nd Stage

RISE (°F)

AIRFLOW (CFM)

AFUE (%)

Steady State (%)

024050N

50,000

—

40,500

—

25-65

575

81.00

81

036060N

60,000

—

50,000

—

20-50

930

80.20

81

036090N

90,000

—

74,000

—

30-60

1150

81.00

81

048060N

60,000

—

50,000

—

20-50

930

80.20

81

048090N

90,000

—

74,000

—

30-60

1150

81.00

81

048120N

120,000

—

101,000

—

40-70

1340

80.70

82

060060N

60,000

—

50,000

—

20-50

930

80.20

81

060090N

90,000

—

74,000

—

30-60

1150

81.00

81

060120N

120,000

—

101,000

—

40-70

1340

80.70

82