p/n: 029-0020-78-0

Attach female eye-bolts, 12 mm, to the
top cross bracket mounting studs for
lifting. Mount the separator tank hav-
ing the inlet port sightly BELOW the
compressor discharge port to ensure
back-flush does not enter the com-
pressor, which would severely damage
the unit. (See Figure A-4: “Lifting Sep-
arator Tank.”)

Mount the tank using 7/16”-14, Grade
8 screws, flat and lock washers and
nuts. For a separator tank mounting
overview schematic, see Section
“Drawing Package” on page 67.

Panel Strainer, Water Cooling

For mounting instructions, see Section 4.4 “Panel Strainer” on page 21.

A.3

PLUMBING CONNECTIONS

(See Figure A-5: “Overview, SMR-AC System Connections,” on page 55.)

The following connections are made by the system builder/installer:

Truck air to solenoid manifold

Gearbox cooler return line to booster tank

Pressure lines (3/8” tube) to PM control

Control line (3/8” tube) from PM control to sensing valve

Switch and truck air to pump master drain

Water and air to duplex master gauge

TRV electrical and discharge connections

TPM electrical connections