SMR-AC Installation and Setup

58

Addendum - SMR-AC CAFSPro Installation Guide

p/n: 029-0020-78-0

Note: A minimum 1” (25.4 mm) connection is required to test the system per
NFPA standards.

A.5

AIR FILTER

For reliable operation, the CAFS air filter must be located in a clean, fresh-
air environment, usually in the dunnage area above the pump compartment.

DO NOT damage the filter during
assembly and be sure the mount-
ing area offers protection.

Mount the air filter 6” (152 mm)
MINIMUM above the decking plat-
form to prevent standing water from
being sucked into the filter and pos-
sibly back into the system. (See
Figure A-8: “Typical Air Filter Instal-
lation,” on page 58.)

Use 3” (76.2 mm) CPVC pipe and
rubber connections. Support the
piping with brackets as needed.

A.6

ELECTRICAL CONNECTIONS

Harness Connections

To

From

Connector

Number

Separator Tank

Air Sensing Valve

C14

Vent Valve

C7

Oil temperature Sensor

C15

Oil Salvage (Blow-Down)

C17

Gearbox

Pump Engaged Switch

C9

Tachometer Sender

C13

Labeled

Apparatus Power

C16

Table A-9: Harness Connections

Figure A-8: Typical Air Filter Installation