background image

Controls and Indicators

26

CAFSPro User Operation Manual

p/n: 029-0020-75-0

Hale Instruction Placard

(See Figure 3-6: “Hale Single and Dual Tank Instruction Placards.”)

Figure 3-6: Hale Single and Dual Tank Instruction Placards

These optional placards provide basic instructions for single or dual tank
operation of the Hale FoamLogix Foam Proportioning System. They are
normally placed on the operator’s panel to meet NFPA requirements for
a “System Diagram.”

Hale CAFSPro Display

(See Figure 3-7: “Hale CAFSPro Control Unit.”)

The CAFSPro display provides the
operator with push button control of
compressed air injection during
CAFS operation.

The CAFS system is energized
when the pump is placed in PUMP
gear. During operation when air is
flowing, the display shows the air
flow rate in SCFM. When the DIS-
PLAY button (i) is pressed, the dis-
play cycles through system infor-
mation displays that include Airflow,
Air-to-Foam Solution Ratio, Com-
pressor Oil Temperature and Com-
pressor Elapsed Run Time.

Figure 3-7: Hale CAFSPro Control Unit