Figure 7-7: hot shift oil sight tube – Hale CAFSPro User Manual

Page 60

Advertising
background image

Routine Maintenance

60

CAFSPro User Operation Manual

p/n: 029-0020-75-0

IMPORTANT !

DISPOSE OF THE WASTE WATER/OIL IN ACCORDANCE WITH YOUR LOCAL
RECYCLING REGULATIONS.

3.

Remove the brass
fitting, containing the
air vent, from the fill
tube hose barb.
(See Figure 7-7:
‘Hot Shift Oil Sight
Tube.’)

4.

Using a squeeze
bottle or funnel, refill
the housing via the
hose bar fitting and
fill hose with Dexron
III or Mercon ATF or
equal, while watch-
ing the oil level
sight gauge
. The
housing holds
approximately
twelve (12) ounces (0.4 liters).

The proper oil level is when the oil level sight tube is filled half way
between the top and bottom.

WARNING !

ALWAYS ALLOW OIL TO SETTLE PRIOR TO CHECKING LEVEL. DO NOT
OVERFILL THE SYSTEM.

THE PROPER OIL LEVEL MUST BE MAINTAINED IN AT ALL TIMES. LOW OIL
LEVEL OR NO OIL COULD RESULT IN EXCESSIVE OPERATING TEMPERA-
TURES CAUSING MAJOR DAMAGE. HIGH OIL LEVEL COULD CAUSE THE
SYSTEM TO MALFUNCTION OR COULD CAUSE A DRIVE FAILURE.

Figure 7-7: Hot Shift Oil Sight Tube