Figure 7-1: maintenance overview – Hale CAFSPro User Manual

Page 52

Advertising
background image

Routine Maintenance

52

CAFSPro User Operation Manual

p/n: 029-0020-75-0

Figure 7-1: Maintenance Overview

2.

Place a suitable container 8 to 10 ounces (237 to 296 ml) under the
compressor drain valve and remove the brass valve plug. (See Figure
7-1: ‘Maintenance Overview.’)

3.

Open the valve and allow the water to drain. The oil drain valve is a 1/4”
NPT ball valve.

Monitor the flow. As soon as pure oil begins flowing, CLOSE the valve.

4.

Replace the brass valve plug in the valve and check the oil level.

IMPORTANT !

DISPOSE OF THE WASTE WATER/OIL IN ACCORDANCE WITH YOUR LOCAL
RECYCLING REGULATIONS.

Note: In humid weather, after short run times, up to 8 ounces (237 ml) of conden-
sation could accumulate. Running the compressor for a longer period automati-
cally removes the moisture through the discharge with the air and heating of the
oil.

Advertising