5 air cleaner element, 6 compressor belt tension adjustment, General – Hale CAFSPro User Manual

Page 56: Figure 7-2: removing the belt guard, Remove belt guard

Advertising
background image

Routine Maintenance

56

CAFSPro User Operation Manual

p/n: 029-0020-75-0

1.

The stainless steel mesh basket pulls out for cleaning.

2.

Clean thoroughly using warm water. Replace if the screen is ripped or
damaged. Order Hale p/n: 010-0670-00-0.

7.5

AIR CLEANER ELEMENT

Change the air cleaner element on the CAFSPro System every time the
engine air filter is changed. Order Hale p/n: 010-0690-00-0.

7.6

COMPRESSOR BELT TENSION ADJUSTMENT

(See Figure 7-3: ‘Belt Tension Gauge’ on page 57.)

General

Proper belt tension is critical
to long equipment life. A
loose belt causes a knock or
bang as the teeth jump. An
over tightened belt overloads
the bearings and leads to
premature wear or failure.

For convenience, an adjust-
ment clearance port in the
belt guard cover is now pro-
vided. If your system
includes this feature, proceed
to heading “To Check Ten-
sion” on page 57.

If your belt guard does not
have the adjustment clear-
ance port the guard must be
removed. See heading
“Remove Belt Guard” below.

Remove Belt Guard

To expose the belt, the belt guard must be removed - 6 screws and hard-
ware. (See Figure 7-2: ‘Removing the Belt Guard.’)

Figure 7-2: Removing the Belt Guard

Advertising