5 Mounting & Connecting the Electrical System

34

5.2.2.2

Dual Air Locker System


c If two Air Lockers are to be installed in the system, ARB

recommends that the switches and solenoids be wired according to
Figure 25. For safety reasons, this configuration allows SOLENOID
2 to be actuated only if SOLENOID 1 is already on.

c Attach the “REAR AIR LOCKER” switch cover to SWITCH 1, and

the “FRONT AIR LOCKER” switch cover to SWITCH 2.

NOTE :

Refer to Figure 23. for the correct switch terminal
identification and switch orientation.


c Configure SOLENOID 1 as the air line leading to the rear axle Air

Locker, and SOLENOID 2 as the air line leading to the front axle Air
Locker
.



















Figure 25.

DUAL AIR LOCKER SYSTEM