Once selected for Temperature Sensor 1, press right soft

key NEXT, and repeat the same process for Temperature
Sensor 2.

Press the left soft key DONE.

To continue set-up, press right soft key NEXT. The following
screen is displayed. See Fig.26.

CALIBRATING TEMPERATURE SENSORS

This selection allows correlation between the room
controller’s sensors and the SmartBox

sensors.

FIG. 26

Press the center soft key EDIT. The following screen is

displayed.

FIG. 27

-- Before making any adjustments, you must allow the

temperature between the room controller sensors
and the SmartBox

sensors to stabilize.

-- Once temperatures have stabilized, use the up/down

keys to enter room temperature sensor offset.

-- Example: If the room controller reads 70 F and the

SmartBox

reads 69 F, set the offset temperature 1F

by pressing the up key.

Press the right soft key NEXT to set temperature offset for

Sensor 2 if used. Use the up/down keys accordingly.

Press the left DONE key.

Press the up/down keys and center soft key

simultaneously to exit the set-up mode and to return you
back to the Home Screen. Now determine your temperature
curve.

DEFINING THE TEMPERATURE CURVE

The SmartBox

has the capacity for 6 time and

temperature control periods.

-- If the existing temperature curve is more than six

periods, it will need to be adjusted for entry into the
SmartBox

.

-- An example is the following:

Period DRT

Day

SmartBox

Set Point

1

82F 1

80F

2 79F 7

77F

3 75F 22 73F
4 72F 35 70F
5 70F 48 68F
6 68F 65 66F

Note: For each Period, the Days must be equal to or

greater than the previous period.

Example: Period 3 cannot start at Day 6.

SET-UP OF ROOM CONTROL

a. Determine the 6 temperature/day period curve.
b. Enter the temperature curve.(Use the previous

example, Day 1)
-- Set DRT to 82 F
-- Set the heat “on” offset to -3F (79F)

c. Set the heat “off” differential to 3F (82F), same as

the DRT.

- The SmartBox

will turn heating off before

temperature exceeds DRT or Set-point.

- This allows the SmartBox

to be enabled to

operate in the range of 79F to 82F.

SET-UP OF SYSTEM TEMPERATURE CURVE

Press the up/down keys and the center sof t key

simultaneously to enter the set-up mode.

Press the right soft key PARAMETERS.

Press the right soft key NEXT to arrive at the Temperature

Curve Input section. See Fig.28.

FIG. 28

To e n te r t h e

temperature, press the center soft key EDIT.

The following screen is displayed.

FIG. 29