Once selected for Temperature Sensor 1, press right soft

key NEXT, and repeat the same process for Temperature
Sensor 2.

■

Press the left soft key DONE.

■

To continue set-up, press right soft key NEXT. The following
screen is displayed. See Fig.26.

CALIBRATING TEMPERATURE SENSORS

This selection allows correlation between the room
controller’s sensors and the SmartBox

™

sensors.

FIG. 26

■

Press the center soft key EDIT. The following screen is

displayed.

FIG. 27

-- Before making any adjustments, you must allow the

temperature between the room controller sensors
and the SmartBox

™

sensors to stabilize.

-- Once temperatures have stabilized, use the up/down

keys to enter room temperature sensor offset.

-- Example: If the room controller reads 70 F and the

SmartBox

™

reads 69 F, set the offset temperature 1F

by pressing the up key.

■

Press the right soft key NEXT to set temperature offset for

Sensor 2 if used. Use the up/down keys accordingly.

■

Press the left DONE key.

■

Press the up/down keys and center soft key

simultaneously to exit the set-up mode and to return you
back to the Home Screen. Now determine your temperature
curve.

DEFINING THE TEMPERATURE CURVE

■

The SmartBox

™

has the capacity for 6 time and

temperature control periods.

-- If the existing temperature curve is more than six

periods, it will need to be adjusted for entry into the
SmartBox

™

.

-- An example is the following:

Period DRT

Day

SmartBox

™

Set Point

1

82F 1

80F

2 79F 7

77F

3 75F 22 73F
4 72F 35 70F
5 70F 48 68F
6 68F 65 66F

Note: For each Period, the Days must be equal to or

greater than the previous period.

Example: Period 3 cannot start at Day 6.

SET-UP OF ROOM CONTROL

a. Determine the 6 temperature/day period curve.
b. Enter the temperature curve.(Use the previous

example, Day 1)
-- Set DRT to 82 F
-- Set the heat “on” offset to -3F (79F)

c. Set the heat “off” differential to 3F (82F), same as

the DRT.

- The SmartBox

™

will turn heating off before

temperature exceeds DRT or Set-point.

- This allows the SmartBox

™

to be enabled to

operate in the range of 79F to 82F.

SET-UP OF SYSTEM TEMPERATURE CURVE

■

Press the up/down keys and the center sof t key

simultaneously to enter the set-up mode.

■

Press the right soft key PARAMETERS.

■

Press the right soft key NEXT to arrive at the Temperature

Curve Input section. See Fig.28.

FIG. 28

■

To e n te r t h e

temperature, press the center soft key EDIT.

The following screen is displayed.

FIG. 29