L.B. White FA-MCS-D User Manual

Page 13

Advertising
background image

Use the up/down keys to set the start temperature.

Press the left soft key DONE.

Press the right soft key NEXT. The following screen is
displayed.

FIG. 30

Press the center soft key EDIT. The following screen is
displayed.

FIG. 31

Press the up/down keys to set the Period 2 day as
determined with the temperature curve.

Press the right hand soft key NEXT. The following screen

is displayed. Enter the desired set point for period 2 using
the up/down keys.

FIG. 32

Press the left hand soft key DONE.

Repeat this same process for Period 3 through 6,
setting the number of days and set points.

Press the left soft key DONE.

Simultaneously press the middle soft key and up/down
keys to return to the Home Screen. Setup is complete.

CYCLE RE-START-RESETTING TO DAY 1

Use the Control Reset Switch when starting a new group
of pigs.

Position the toggle switch on the control panel from On,
to Off, and then to On. This resets the system back to a
new day 1 scheduled start day.

SCREEN DISPLAYS

-- Z1 TMP OR ( Zone Temperature Override, Manual

Mode)

-- Z1 OR EN (Zone 1 Override Enabled)

-- Z2 OR EN (Zone 2 Overide Enabled)
-- Z1 OR ENA or dSA (Zone 1 enabled or disabled)
-- Z1 TSP OR ( Zone 1 Temperature Set Point Override)
-- Z2 TSP OR (Zone 2 Temperature Set Point Override)
-- STRT DAY (Start Day)
-- Time
-- SCHD DAY (Schedule Day)
-- ACT Period (Actual Period)
-- RMNG HRS (Remaining Hours)
-- Z1 ACTSP (Zone 1 Actual Set point)
-- Z2 ACTSP (Zone 2 Actual Set Point)
-- Z1 T1 (Zone 1 Temperature Sensor 1)
-- Z1 T2 (Zone 1 Temperature Sensor 2)
-- Z2 T1 ( Zone 2 Temperature Sensor 1)
-- Z2 T2 (Zone 2 Temperature Sensor 2)
-- Z1 T Avg (Zone 1 Temperature Sensor Average)
-- Z2 T Avg (Zone 2 Temperature Sensor Average)
-- SCHED ER (Schedule Error)
-- Z1 Htg Ld (Zone 1 Heating Load)*
-- Z2 Htg Ld (Zone 2 Heating Load)*
-- P1 T SP(Period 1 through 6 Temperature Set Point)
-- P2 Day (Period 2 Day through Period 6 Day)
-- Sen Dis (Sensor Disabled)
-- Dis T1 (Temperature Sensor 1 Disabled)
-- Dis T2 (Temperature Sensor 2 Disabled)
-- TMP OF SET( Temperature off set)
-- OF ST T1 (or T2) (Off set Temperature Sensor 1 or 2)

-- Set Clk (Set Clock)
-- Month
-- Day
-- Year
-- Hour
-- Minutes

* Percentage of operation of Smart Valve

13