L.B. White FA-MCS-D User Manual

Page 13

Advertising
background image

■

Use the up/down keys to set the start temperature.

■

Press the left soft key DONE.

■

Press the right soft key NEXT. The following screen is
displayed.

FIG. 30

■

Press the center soft key EDIT. The following screen is
displayed.

FIG. 31

■

Press the up/down keys to set the Period 2 day as
determined with the temperature curve.

■

Press the right hand soft key NEXT. The following screen

is displayed. Enter the desired set point for period 2 using
the up/down keys.

FIG. 32

■

Press the left hand soft key DONE.

■

Repeat this same process for Period 3 through 6,
setting the number of days and set points.

■

Press the left soft key DONE.

■

Simultaneously press the middle soft key and up/down
keys to return to the Home Screen. Setup is complete.

CYCLE RE-START-RESETTING TO DAY 1

■

Use the Control Reset Switch when starting a new group
of pigs.

■

Position the toggle switch on the control panel from On,
to Off, and then to On. This resets the system back to a
new day 1 scheduled start day.

SCREEN DISPLAYS

-- Z1 TMP OR ( Zone Temperature Override, Manual

Mode)

-- Z1 OR EN (Zone 1 Override Enabled)

-- Z2 OR EN (Zone 2 Overide Enabled)
-- Z1 OR ENA or dSA (Zone 1 enabled or disabled)
-- Z1 TSP OR ( Zone 1 Temperature Set Point Override)
-- Z2 TSP OR (Zone 2 Temperature Set Point Override)
-- STRT DAY (Start Day)
-- Time
-- SCHD DAY (Schedule Day)
-- ACT Period (Actual Period)
-- RMNG HRS (Remaining Hours)
-- Z1 ACTSP (Zone 1 Actual Set point)
-- Z2 ACTSP (Zone 2 Actual Set Point)
-- Z1 T1 (Zone 1 Temperature Sensor 1)
-- Z1 T2 (Zone 1 Temperature Sensor 2)
-- Z2 T1 ( Zone 2 Temperature Sensor 1)
-- Z2 T2 (Zone 2 Temperature Sensor 2)
-- Z1 T Avg (Zone 1 Temperature Sensor Average)
-- Z2 T Avg (Zone 2 Temperature Sensor Average)
-- SCHED ER (Schedule Error)
-- Z1 Htg Ld (Zone 1 Heating Load)*
-- Z2 Htg Ld (Zone 2 Heating Load)*
-- P1 T SP(Period 1 through 6 Temperature Set Point)
-- P2 Day (Period 2 Day through Period 6 Day)
-- Sen Dis (Sensor Disabled)
-- Dis T1 (Temperature Sensor 1 Disabled)
-- Dis T2 (Temperature Sensor 2 Disabled)
-- TMP OF SET( Temperature off set)
-- OF ST T1 (or T2) (Off set Temperature Sensor 1 or 2)

-- Set Clk (Set Clock)
-- Month
-- Day
-- Year
-- Hour
-- Minutes

* Percentage of operation of Smart Valve