Interconnection – L.B. White FA-MCS-D User Manual

Page 7

Advertising
background image

■

Unlatch the control box cover, and open the control
panel.

■

Select locations on either the side or the bottom where
a wiring access holes may be drilled. Do not drill holes
at the top of the control box.

■

Install the appropriate sized water tight connectors.

■

Refer to the following for connection instructions. Refer
to t h e w h i te f l a g s o n t h e Smar tBox

™

l e a d s fo r

interconnections.

Connecting 120 VAC Power Supply to the SmartBox

™

.

Connect to hot, neutral, and ground leads as shown in
Fig.6.

FIG. 6

Connecting 120 VAC Power to the Heaters

Connect leads in SmartBox

™

to heating Zones 1 and 2.

See Fig.7.

FIG. 7

Wiring from the SmartBox

™

to the heater’s Smart Sense

™

variable rate gas control valve

a. Connect Smart Sense™ gas control valve wiring

for Zones 1 and 2 at SmartBox

™

leads as

shown in Fig.8.

FIG. 8

b. Route the wiring from these leads through the

gas inlet hole at the heater’s case. See Fig.9.

c. Attach 1/4 in. insulated female terminals to

these wires and connect to either terminal on
the valve. See Fig. 9.

FIG. 9

7

Interconnection

ROUTE WIRING
THROUGH HOLE

CONNECT WIRING TO TERMINALS
( NOT POLARITY SENSITIVE)

WARNING

Electrical Shock Hazard

■

Disconnect the electrical supply before installation of

the SmartBox

™

.

■

Failure to follow this warning may result in personal
injury or death.