SkyTrak 3606 Service Manual User Manual

Page 375

Advertising
background image

Electrical System

10-57

Model 3606 • Origin 10/99

a. Thermo-Start Plug Removal

1. Label and disconnect the thermo-start wiring lead at

the thermo-start plug electrical connector.

2. Disconnect the fuel line.

3. Remove the thermo-start plug by unthreading it from

the intake manifold.

b. Disassembly

DO NOT disassemble the thermo-start plug. Replace a
defective plug with a new one.

c. Cleaning and Drying

DO NOT submerge the thermo-start plug. Clean the
exterior of the plug in an approved solvent. Dry the plug
with a clean, lint-free cloth.

d. Inspection and replacement

Examine the fuel line and the thermo-start plug mounting
bore in the intake manifold for any contamination and
clean as required.

Test the thermo-start plug coil using short, heavy-gauge
wires connected to a fused or otherwise protected 6-amp
minimum output, 12-volt DC power supply. If the coil fails
to heat, replace the thermo-start plug with a new one.

e. Thermo-start Plug Installation

1. Thread the thermo-start plug (Fig. 10– 56) into its

mounting bore in the intake manifold.

2. Connect the fuel line to the thermo-start plug.

3. Connect the wiring lead to the thermo-start plug

terminal.

10.8.5 Fuel Run Solenoid

The fuel run solenoids a valve that lets fuel enter the
injection pump when the ignition switch is turned to the
START or RUN positions. The fuel run solenoid is located
as follows:

On the side of the fuel injection pump (2, Fig. 10– 57).

Figure 10– 57. Perkins engine fuel-run solenoid.

On the rear of the fuel injection pump, connected to
mechanical linkage (2, Fig. 10– 58).

Figure 10– 58. Cummins engine fuel-run solenoid.

PERKINS ENGINE

1. Fuel Injector Pump

2. Fuel-run Solenoid

MS2450

1

2

CUMMINS ENGINE

1. Fuel Injector Pump

2. Fuel-run Solenoid

MS1690

1

2

Advertising