SkyTrak 3606 Service Manual User Manual

Page 382

Advertising
background image

Section 10

10-64

Model 3606 • Origin 10/99

d. Transmission Solenoid Valve Installation

1. Carefully install the four-way cartridge valve

assembly with four new O-rings (8, 9, 10 and 11, Fig.
10– 69)
into the transmission. Always replace used O-
rings with new O-rings.

2. Install an O-ring (5) on each side of the 12-volt

solenoid coil (6). Always replace used O-rings with
new O-rings. Install the 12-volt solenoid coil onto the
cartridge valve (7).

3. Install the valve cartridge retainer nut (4) securing the

12-volt solenoid coil to the transmission.

4. Install the protective cover (1), lockwashers (2) and

cover screws (3) over the transmission solenoid
valves.

5. Refer to the chart listed earlier under 10.8.11

Transmission Solenoid Valves. Connect the
transmission solenoid valve(s) with the proper wiring
connector(s).

6. Connect the negative (-) battery cable to the negative

battery terminal (Fig. 10– 70).

7. Test the operation of the transmission. Put the

transmission through its entire range of gears
(speeds) in both FORWARD (F) and REVERSE (R)
and check that the transmission also shifts into
NEUTRAL (N).

8. Verify that each function works properly, that the

transmission does not engage when in NEUTRAL
(N) and that the proper indicators illuminate on the
operators display panel.

For further transmission information, refer to Section 7
Transmission
and to the Clark-Hurth T 12000 transmis-
sion service manual.

Figure 10– 71. Disconnect the negative (-) battery cable

at the negative (-) battery terminal.

OS1040

Negative (-)
Terminal

Advertising