DESIGN & FIELD HEMMING
Installed Panel Cross Section
Seal with Tube Sealant
Panel Clip
Factory
Mastic
MSL Panel
Panel Clip Installation
Factory
Mastic
Panel Clip
MSL Panel
NOTE
1. Fill end of panel seam at eave and
valleys with sealant.
2. For UL 90 rating, UL 90 clips with two
fasteners must be used.
1 1/2"
1½"
1½"
½"
½"
1"
PANEL
ENGAGEMENT
Mueller Snap
Lock Panel
Hemming Tool
Field Cut-Out
Field Cut-Out
Design
Field Hemming