Lull 1044C-54 Series II Service Manual User Manual

Page 125

Advertising
background image

Supply, Pressure, and Return Hydraulics

31200079

5-43

Removal

Mid-Inlet Control Valve

Fig. 5-28: Mid-Inlet Control Valve Installation

(Ref. Fig. 5-28) The following procedure describes removal of the mid-inlet
control valve.

1. Follow preparation procedures as outlined in Section 3.

2. Install a brake pressure diagnostic test gauge onto the “Brakes”

diagnostic port.

3. While watching the test gauge, press the brake pedal numerous times

until the pressure gauge reads 0 psi. Remove the test gauge and cap
the diagnostic port.

4. Tag and disconnect all hydraulic lines from control valve fittings. Cap all

hoses, tubes, and fittings. Tag all fittings.

5. Remove three (3) capscrews and lockwashers securing the mid-inlet

control valve to the valve plate.

6. Using appropriate lifting devices, lift the control valve from valve plate

and take to an appropriate location for disassembly and cleaning.

K

1142

Capscrew

Lockwasher

Valve Plate

Control Valve

Advertising