10.3.4 Changing the blade and hand guard of combi tool

1. First of all, carefully clean the rescue equipment.
2. Next, close the blade arms so that the tips are almost touching.

Further procedure:

3. Remove screws A and spring washers B

of handle C.

The handle can then be removed in the
direction of the connecting hoses of the
device.

4. Remove nut D and washer E from

the pivot bolt.

5. Press the pivot bolt F out.

6. Push the hand guard G in the

depicted direction until the safety
bolts H are easily accessible.

7. Remove retaining rings J.

A

B

C

D

E

F

G

H

J

REMARK:
The blade bolts are only accessible when the blade arms are almost touching