INSTALLATION - ABOVE GRADE PLUMBING
Installation Guidelines
• Use 1.5 inch to 2.0 inch ID plumbing to connect
operatory lines to separation tank.
• Plumbing lines should be sloped down to the
separation tank as shown in the schematic
(minimum slope of 1/32 inch per foot).
• A maximum of a 10-foot rise is recommended
for above-grade plumbing. If more than 10 feet
of rise is required, contact your distributor.
• Low spots in the line should be avoided to
prevent flow restriction or vacuum loss.
• It may be necessary to upgrade to the next
largest system for an operatory with above-grade
plumbing.
• All plumbing entering the main trunk line needs
to be dropped in on the top of the trunk line as
shown in the schematic.
the separation tank
Minimum 1.5" ID Pipe
Lines to Operatory
Slope pipe down towards
Ground Level
Max 10
Feet Height
Connection must
be higher than
tank inlet