Chapter 8 – Prestart Inspection

22

0120843-ANSI PUSH PRO 6,8,10

Casters/Tires

Visually inspect the casters / tires (refer to Figure 8.8) to

make sure they are suitable for service.

Figure 8.8 – Casters/Tires

To inspect the Casters/Tires:

1. Visually inspect the tires. They should be smooth

without any cuts, gouges, or missing rubber that

might affect aerial platform stability.

2. Check the casters to see that the fasteners are in

place and are not damaged or loose.

Lower Control Station

With no personnel or materials in the platform, test the

operation of each control from the lower controls (refer

to Figure 8.9).

Figure 8.9 – Lower Controls

Operating Controls

Use the following procedure to operate and test the ma-

chine from the lower controls:

1. Pull the emergency stop button outward (refer to

Figure 8.10).

2. Insert the key into the control selector switch and

turn the switch to the lower controls position.

3. Press and hold the ground operation button

inward.

• To raise the platform, press and hold the

platform raise button.

• To lower the platform, press and hold the

platform lower button.

4. Release the button to stop movement.

Danger

Pinch points may exist between moving components.

Death or serious injury will result from becoming

trapped between components, buildings, structures,

or other obstacles. Make sure all personnel stand

clear of the aerial platform while performing the pre-

start inspection.

Warning

The potential for an accident increases when operat-

ing an aerial platform that is damaged or malfunction-

ing. Death or serious injury could result from such

accidents. Do not operate the aerial platform if it is

damaged or malfunctioning.

5. Test the operation of the platform raise/lower switch

in both directions.

6. Place the Control Selector switch in the off position.

The platform should not raise or lower with the switch

in this position.

Emergency Stop

To test the emergency stop button from the lower

controls:

1. Push the emergency stop button inward to turn off

electrical power.

2. Test the lower control functions to make sure they do

not operate with the emergency stop in this position.

Lowering Alarm

To test the lowering alarm from the lower controls:

1. Raise the platform approximately 6′ (1.8 m).

2. Lower the platform and make sure the alarm sounds.

Emergency