Chapter 8 – Prestart Inspection

0120843-ANSI PUSH PRO 6,8,10

25

Battery Condition Indicator

The battery condition indicator (refer to Figure 8.15) is

located on the upper control panel.

Figure 8.15 – Upper Controls

With the machine set up to operate from the upper con-

trols, check to see that the battery condition indicator

gauge displays a power reading.

Placards and Decals

To inspect the placards and decals:

1. Inspect all safety and operational placards and de-

cals. Make certain they are in place, in good condi-

tion, and are legible.

2. Clean the placards and decals with soap and water,

and a soft cloth if the words or pictures cannot be

seen.

Caution

Solvents may contain hazardous ingredients. Follow

the manufacturer’s label for proper use and disposal.

Wear protective gloves and splash-proof safety

glasses when using solvents.

3. Remove wet paint overspray with a natural biode-

gradable solvent and a soft cloth.

4. Replace any missing, damaged, or illegible placards

or decals before operating the aerial platform.

Placard and decal kits are available from Snorkel.

The safety related placards and decals are illustrated on

the following pages.

7. Raising and Lowering : Press and hold the interlock

button on the left side of the upper control box.

• To raise the platform, press and hold the platform

raise button until the desired height is reached.

• To lower the platform, press and hold the platform

lower button until the desired height is reached.

Lowering Interrupt

When the platform is lowered to about 5’ (1.5 m)

lowering stops. The platform will not lower for five

seconds regardless of the joystick position.

Release the platform lower button to reset the lowering

function, then continue to lower the platform

Emergency Stop

To test the emergency stop button from the upper controls:

1. Push the emergency stop button inward to turn off

electrical power.

2. Verify that the upper control platform and drive func-

tions do not operate.

Lowering Alarm

To test the lowering alarm from the upper controls:

1. Raise the platform approximately 5′ (1.5 m).

2. Lower the platform and make sure the alarm sounds.

Flashing Light

The machine may be equipped with an optional flashing

light mounted on the side of the machine.

To inspect the flashing light:

1. At the lower controls, pull the emergency stop button

outward and turn the control selector switch to either

the lower or upper control position.

2. Operate any control function and visually check to

see that the light is flashing approximately one flash

per second.

Note

There is not an off switch for the flashing light.