SECTION 4 - MACHINE OPERATION

4-2

– JLG Lift –

3120828

4.2

GENERAL

This section provides the necessary information needed

to operate the machine. Included in this section are the

procedures for starting, stopping, traveling, steering, park-

ing, platform loading and transporting. It is important that

the user read and understand the proper procedures

before operating the machine.

4.3

ENGINE OPERATION

NOTICE

RTS SERIES SCISSOR LIFTS MANUFACTURED AFTER AUGUST
26, 1996 ARE EQUIPPED WITH A HYDRAULIC OIL TEMPERATURE
SWITCH THAT SHUTS DOWN THE ENGINE WHEN THE HYDRAU-
LIC OIL REACHES A TEMPERATURE OF APPROXIMATELY 111˚C
(230˚F). THIS SHUT DOWN IS INTENDED TO PROTECT THE
HYDRAULIC SYSTEM AND ITS COMPONENTS FROM DAMAGE
DUE TO EXCESSIVE HEAT. HEAT MAY BUILD UP DUE TO
EXTENDED DRIVING, IN CONJUNCTION WITH HIGH AMBIENT
TEMPERATURES, ACTIVATING THIS SWITCH AND SHUTTING
DOWN THE MACHINE. IF THE MACHINE SHUTS DOWN, ALLOW
THE HYDRAULIC OIL TO COOL, THEN RESUME NORMAL OPERA-
TION.

NOTE: Initial starting should always be performed from the

Ground Control Station.

Starting Procedure

1.

Check engine oil before attempting to start engine; if
necessary, add oil in accordance with Engine Manu-
facturers Manual.

2.

Pull the red mushroom-type Ignition/Emergency
Stop switch at the Ground Control Station to the UP
position (ON).

3.

Place the PLATFORM/GROUND SELECT switch to
the applicable position for desired control station
operation.

4.

If operating a dual fuel machine, place the LP/GAS-
OLINE SELECT switch to the desired position.

NOTE: If LPG system is selected, ensure that the hand

valve on the LPG supply tank is opened prior to
attempting to start the engine.

NOTICE

IF ENGINE FAILS TO START PROMPTLY, DO NOT CRANK FOR AN
EXTENDED PERIOD. SHOULD ENGINE FAIL TO START ONCE
AGAIN, ALLOW STARTER TO “COOL OFF” FOR 2 TO 3 MINUTES.
IF ENGINE FAILS TO START AFTER SEVERAL ATTEMPTS, REFER
TO ENGINE MAINTENANCE MANUAL.

NOTE: If starting machine from the platform control station,

place the engine speed control switch to the LOW
position prior to starting the engine.

5.

If starting machine from ground controls, position
IGNITION/EMERGENCY STOP switch to ON and
depress START button and hold until engine starts.
If starting from platform controls, position POWER
ON switch to ON and depress START button and
hold until engine starts.

6.

Check engine voltmeter when starting engine and
monitor gauge periodically during operation.

NOTICE

ALLOW ENGINE TO WARM-UP FOR A FEW MINUTES AT LOW
SPEED BEFORE APPLYING ANY LOAD.

7.

After engine has had sufficient time to warm up, pro-
ceed with operation of unit.

Table 4-1. Operating Specifications

Model

400RTS

500RTS

Maximum Occupants

4

4

Maximum Workload (Capacity)
Extension Only:

680 kg

900 kg

Maximum Travel Grade (Gradeability)
2 WD
4WD

35%
45%

35%
45%

Maximum Travel Grade (Sideslope)

2 degreess

2 degreess

Maximum Platform Height

12.1m

15.2m

Maximum Tire Load

Reference Decal on Machine

Approximate Maximum Drive Speed
2 Wheel Drive
4 Wheel Drive

5.6 kmh
4.5 kmh

5.6 kmh
4.5 kmh

Approximate Gross Machine Weight

6,797 kg

6,940 kg