SECTION 1 - SPECIFICATIONS

1-6

– JLG Lift –

3120869

18

Air Filter - Deutz

Replaceable

Element

N/A

N/A

X

Or as indicated by condition indicator

19

Air Filter - Isuzu

Replaceable

Element

N/A

N/A

X

Or as indicated by condition indicator

NOTES:

KEY TO LUBRICANTS

Lubrication intervals are based on machine operation under normal conditions. For machines used in multi shift operations and/or exposed to hostile envi-
ronments or conditions, lubrication frequencies must be increased accordingly.

EO

EPGL

HO

MPG

OGL

Engine Oil
Extreme Pressure Gear Lube
Hydraulic Fluid (Mobil DTE-11M)
Multi-Purpose Grease
Open Gear Lubricant - Mobiltac 375 or
equivalent

* If necessary install grease fittings into worm gear housing and grease bearings.

DO NOT OVERGREASE BEARINGS. OVERGREASING BEARINGS WILL RESULT IN
BLOWING OUTER SEAL IN HOUSING.

**When changing oil in the Deutz oil cooled engine, drain both the crankcase and the cooler. When refilling it is acceptable to overfill crankcase (10.5 L),
capacity of both crankcase and cooler combined). Start engine, allow the engine to run until the thermostat opens (approximately 105 degrees C) cooler will
fill up within minutes; shut down and wait for approximately two minutes. Check oil level, fill oil to max marking on dipstick.

Table 1-8. Lubrication Chart

Components

Number/Type

Lube Points

Capacity

Lube

Interval

Hours

Comments

3

Months
150 hrs

6

Months
300 hrs

1 Year

600 hrs

2 Years

1200 hrs

Updated 11-1-99