Operation and Safety and ANSI
Responsibilities Manual

Ensure a copy of manual is enclosed in the manual stor-
age box.

Lubrication

For those parts pointed out in the Walk-Around Inspection
requiring lubrication, refer to the Lubrication Chart, Table
2-1., for specific time interval requirements.

Hydraulic oils must have anti-wear qualities at least to API
Service Classification GL-3, and sufficient chemical stabil-
ity for mobile hydraulic system service. JLG Industries,
recommends Mobilfluid 424 hydraulic oil, which has an
SAE viscosity of 10W-30 and a viscosity index of 152.

For cold weather applications, i.e. when temperatures
remain consistently below +20°F (–7°C) JLG recom-
mends using Mobil DTE 13 hydraulic oil.

2.5

DAILY FUNCTIONAL CHECK

TO AVOID INJURY DO NOT OPERATE A MACHINE UNTIL ALL
MALFUNCTIONS HAVE BEEN CORRECTED. USE OF A MALFUNC-
TIONING MACHINE IS A SAFETY VIOLATION.

Once the Walk-Around Inspection is complete, a Func-
tional Check of all systems should be performed in an
area free of overhead and ground level obstructions. Per-
form a Functional Check in accordance with the following
procedures:

Set-up machine for operation, according to instructions in
Section 4-3, “Machine Operation”.

NOTE: 20VP MODELS WITH UNDERWRITERS LABORA-

TORY (EE) RATING OPTION ONLY, include a mas-
ter ON/OFF switch located on top of the rear cover of
the machine. This control must be set to the ON
position before the following function checks can be
completed.

Figure 2-1. Daily Walk-Around Inspection.

1

1

2

3

4

5

6

7

8

9

Daily Walk-Around

Inspection Items

1. Drive and Castor Wheels

2. Base Frame

3. Battery/Battery Charger

4. Motor/Pump/Reservoir Unit

5. Ground Controls

6. Mast Assembly

7. Manual Brake ReleaseControl

8. Platform Assembly

9. Platform Controls