JLG 20VP (3120727) Operator Manual User Manual

Page 36

Advertising
background image

SECTION 4 - MACHINE OPERATION

4-2

– JLG Lift –

3120727

4.3

MACHINE OPERATION

The following sequence of basic procedures must be fol-
lowed to safely operate the machine.

1.

At the ground control station, set power PLAT/OFF/
GRND key switch to the PLAT position to operate
from platform controller, or GRND to operate from
ground controls.

2.

Check that the EMERGENCY STOP button at the
ground and platform controls are in the RESET posi-
tion for operation. Also check that EMERGENCY/
MANUAL DECENT CONTROL VALVE is CLOSED
(lower access hole in rear cover).

NOTE: 20VP MACHINES WITH THE UL-EE OPTION ONLY -

These machines are equipped with a master ON/
OFF switch mounted on the rear cover of the
machine. This switch must be set to the ON position
to operate the machine.

3.

Check LED strip on the platform controller for cur-
rent battery charge level before operating lift to be
certain charge is sufficient to complete your work
task. If the battery charger is plugged into an AC
outlet, drive functions on the machine will be locked
out.

NOTE: If LED’S are flashing a fault code on the platform

controller box at machine power-up, see Section-3,
“Troubleshooting” of the Service and Maintenance
Manual for information on reading fault codes.

WORK AREA MUST BE A SMOOTH, FIRM AND LEVEL SURFACE
FREE OF HOLES, LARGE CRACKS OR DEBRIS ON SURFACE.
THE WORK SURFACE MUST BE CAPABLE OF SUPPORTING THE
WEIGHT OF THE MACHINE PLUS THE PLATFORM’S MAXIMUM
RATED LOAD CAPACITY. ALWAYS CHECK THE BUBBLE LEVEL
INDICATOR ON BASE FRAME TO BE SURE MACHINE IS LEVEL
BEFORE RAISING PLATFORM.

4.

Inspect work area before operating lift.

Platform Loading

The platform maximum rated load capacity is displayed
on a decal located on the platform. The maximum rated
load capacity includes the combined weight of the opera-
tor and any materials, tools, etc. placed in the platform
with the operator.

Maximum rated load capacity for all platforms (Except
Extendible)
is as follows:

* Extendible Platform available only for 20VP.

Interlock Switch Operating Conditions

Table 4-3. shown, lists machine response to various inter-
lock switch positions.

Table 4-1. Maximum Rated Load Capacity

(for all platforms except Extendible)

Model

Max. Capacity

10VP

350 lb. (159 kg)

15VP

350 lb. (159 kg)

20VP

350 lb. (159 kg)

Table 4-2. Maximum Rated Load Capacity

(for Extendible Platform*)

Model

Max. Capacity

(ANSI - U.S.A.)

Max. Capacity

(C.S.A. - Canada)

10VP

Not Available*

Not Available*

15VP

Not Available*

Not Available*

20VP

350/300 lb. (160/135 kg)

350/250 lb. (160/114 kg)

Table 4-3.

Machine Interlock Switch Operating Conditions.

Elevation/

Speed Switch

Drive Cutout

(PHP System)

Tilt Status

Brake Status

Controller Response

mast retracted

bars raised

(not tilted)

engaged

Full Drive and Lift

mast retracted

bars raised

(not tilted)

disengaged

Drive and Lift disabled

mast extended

bars lowered

(not tilted)

engaged

Drive 25% maximum

mast extended

bars lowered

(not tilted)

engaged

Drive disabled

mast retracted

bars raised

(tilt)

engaged

Lift disabled

mast retracted

bars raised

(tilt)

disengaged

Drive and Lift disabled

mast retracted

bars raised/battery charger

plugged-in

(not tilted)

engaged

Drive disabled