SECTION 2 - PREPARATION AND INSPECTION

3120727

– JLG Lift –

2-5

2.7

BATTERY CHARGING & MAINTENANCE

VP Models are equipped with 24 volt, 10 amp output bat-
tery chargers (U.S.A. - 120 Volt AC input/60Hz and Brazil -
220 Volt AC input/60 Hz)
. The battery charger includes a
microprocessor controlled automatic charge sensing cir-
cuit which can determine cell voltage and regulate
charger output as required. The charger automatically ter-
minates charging when a full battery charge is acheived.
Also a built-in interlock device prohibits driving the
machine while the battery charger is plugged in.

Battery Maintenance and Safety Practices

(Refer to Figure 2-2.)

ENSURE THAT BATTERY ACID DOES NOT COME INTO CONTACT
WITH SKIN OR CLOTHING. WEAR PROTECTIVE CLOTHING AND
EYEWEAR WHEN WORKING WITH BATTERIES. NEUTRALIZE ANY
BATTERY ACID SPILLS WITH BAKING SODA AND WATER.

BATTERY ACID RELEASES AN EXPLOSIVE GAS WHILE CHARG-
ING, ALLOW NO OPEN FLAMES, SPARKS OR LIGHTED TOBACCO
PRODUCTS IN THE AREA WHILE CHARGING BATTERIES.
CHARGE BATTERIES ONLY IN A WELL VENTILATED AREA.

ADD ONLY DISTILLED WATER TO BATTERIES. WHEN ADDING
DISTILLED WATER TO THE BATTERIES, A NON-METALLIC CON-
TAINER AND/OR FUNNEL MUST BE USED.

As with any wet cell battery, check the electrolyte level of
the batteries often, adding only distilled water when
required. When fully charged, battery fluid level should be
1/8" below vent tubes. (See Figure 2-2.).

• DO NOT fill to bottom of vent tubes.

• DO NOT allow fluid level to go below the top of the

plates when charging or operating.

Battery Charger Operation

(Refer to Figure 2-3 & 2-4.)

1.

Position machine in well ventilated area near an AC
electrical outlet and set the Ground Control-PLAT/
OFF/GRND key switch to the OFF position.

2.

Open the left battery cover and unwrap the battery
charger AC power cable from under the cover.

Figure 2-2. Battery Fluid Level.

Figure 2-3. Charger Assembly and

Power Cord Storage.

1/8 "

BATTERY

FILLER CAP

FLUID LEVEL OF FULLY

CHARGED BATTERY

VENT TUBE

PLATES

KEY

SWITCH

CORD

STORAGE

AREA

BATTERY

CHARGER

Advertising