Load Stability Indicator - LSI

The LSI (1) provides visual and audible indication of forward stability limitations when
machine is static on firm, level surface.

• Green LED (2) will illuminate when LSI power is on.

• When approaching forward stability limitations LEDs progressively illuminate, green

(3), then orange (4) and finally red (5).

• If the red LED illuminates the warning buzzer also sounds.

• As the telehandler reaches forward stability limitations and the red LED (5) illuminates,

the automatic function cut-out is activated. All boom, frame level and outrigger
functions are disabled except for boom retract (CE & AUS) and boom lift (CE). Retract
boom to re-enable functions.

• In some instances the LSI system may slow down or stop boom functions if operated

close to forward stability limitations. When LEDs begin to flash, certain functions can
not be operated. Retract boom and/or return the joystick to neutral position for a
short period to allow system to reset and LEDs to stop flashing before proceeding
with operation.

WARNING

TIP OVER HAZARD. The LSI considers only longitudinal stability limitations, observe
all operating parameters. Failure to follow operating parameters of the telehandler
could damage the equipment and/or cause tip over.