Relief valves, Crossover relief valves, 6 component functional description – JLG 40RTS Service Manual User Manual

Page 20: Piston hydraulic pump, Gear hydraulic pump, Manual descent valve, 7 sliding wear pads, 8 pump and coupling lubrication, 9 cylinder checking procedures, Component functional description -4

Advertising
background image

SECTION 2 - PROCEDURES

2-4

– JLG Sizzor –

3120826

Relief Valves

Main relief valves are installed at various points within the
hydraulic system to protect associated systems and com-
ponents against excessive pressure. Excessive pressure
can be developed when a cylinder reaches its limit of
travel and the flow of pressurized fluid continues from the
system control. The relief valve provides an alternate path
for the continuing flow from the pump, thus preventing
rupture of the cylinder, hydraulic line or fitting. Complete
failure of the system pump is also avoided by relieving cir-
cuit pressure. The relief valve is installed in the circuit
between the pump outlet (pressure line) and the cylinder
of the circuit, generally as an integral part of the system
valve bank. Relief pressures are set slightly higher than
the load requirement, with the valve diverting excess
pump delivery back to the reservoir when operating pres-
sure of the component is reached.

Crossover Relief Valves

Crossover relief valves are used in circuits where the actu-
ator requires an operating pressure lower than that sup-
plied to the system. When the circuit is activated and the
required pressure at the actuator is developed, the cross-
over relief diverts excess pump flow to the reservoir. Indi-
vidual, integral relief’s are provided for each side of the
circuit.

2.6

COMPONENT FUNCTIONAL
DESCRIPTION

Piston Hydraulic Pump

The Sundstrand piston hydraulic pump is attached to and
driven by the engine. The pump is a 45.9 cm[3] (2.8 in.[3])
displacement piston pump that powers the drive motors.

Gear Hydraulic Pump

The John Barnes gear pump is “piggy-backed” to the pis-
ton pump, and operates all machine functions except
drive. The gear pump has a displacement of 10.5 cm[3]
(0.6 in. [3]).

Manual Descent Valve

The manual descent valve is located on top of the holding
valve on the lift cylinder. The holding valve is a normally
closed solenoid valve, and holds the platform in place
when raised. When activated, the valve opens to permit lift
down. The holding valve is connected to the manual
descent valve, which is connected to a cable which, when
pulled, manually opens the lift down port of the valve and
allows the platform to be lowered in the event hydraulic
power is lost.

2.7

SLIDING WEAR PADS

The original thickness of the sliding pads is 50.8 mm (2.0
in.). Replace sliding pads when worn to 47.5 mm (1.87in.).

2.8

PUMP AND COUPLING LUBRICATION

To insure proper operation and a long service life for the
Hayes pump coupling, it is necessary to lubricate the
splines of the coupling any time the coupling is disassem-
bled or replaced. Lubricate the splines with Texaco Code
1912 Pump Coupling Grease ONLY. No other lubricant is
recommended.

2.9

CYLINDER CHECKING PROCEDURES

NOTE: Cylinder checks must be performed any time a cylin-

der component is replaced or when improper system
operation is suspected.

Cylinder w/o Counterbalance Valves - Steer
Cylinder, Axle Lockout Cylinder (If
Equipped)

OPERATE FUNCTIONS FROM GROUND CONTROL STATION
ONLY.

1.

Using all applicable safety precautions, activate
hydraulic system and fully extend cylinder to be
checked. Shut down hydraulic system.

Figure 2-1. Pump and Coupling Lubrication

Advertising
This manual is related to the following products: