Table 3-1. Platform Assembly - Troubleshooting

TROUBLE

PROBABLE CAUSE

REMEDY

No response to control switch

Enable switch not activated

Activate enable switch

Function not activated within the 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Lift control switch inoperative

Repair or replace lift control switch

Hydraulic system oil low

Replenish oil as necessary

No power supply

See wiring diagram

Restricted or broken supply line on valve bank or
hydraulic pump

Clean, repair or replace line

Control valve not functioning properly

Repair or replace valve

Defective dump valve on cylinder

Repair or replace dump valve

Lift cylinder not functioning properly

Repair or replace lift cylinder

Hydraulic pump not functioning properly

Repair or replace hydraulic pump

Platform will not raise

Enable switch not activated

Activate enable switch

Function not activated within the 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Load capacity exceeded. (Personnel and/or equip-
ment.)

Reduce load. (Refer to capacity placard.)

Hydraulic system oil low

Replenish oil as necessary

Broken or binding pivot pin

Repair or replace pivot pin

Restricted or broken hydraulic line or fitting

Clean, repair or replace line or fitting

Control valve not functioning properly

Repair or replace control valve

Lift cylinder not functioning properly

Repair or replace lift cylinder

Pump does not respond when lift control switch is
moved to the up position

Refer to electrical troubleshooting table

No electrical signal being sent to lift up control valve
cartridge

Refer to electrical troubleshooting table

Platform will not lower

Enable switch not activated

Activate enable switch

Function not activated within the 3 seconds after
enable switch was depressed

Reactivate enable switch

Enable switch not functioning properly

Replace enable switch circuit card

Pump does not respond when lift control switch is
moved to the down position

Refer to electrical troubleshooting table

No electrical signal being sent to lift down control
valve cartridge

Refer to electrical troubleshooting table

Lift down control valve cartridge not functioning
properly

Repair or replace lift down control valve cartridge

Lift cylinder not functioning properly

Repair or replace lift cylinder